Xmtg2000 Temperature Controller Manual Pdf Top

Offers automatic tuning to achieve accurate, stable temperature management.

The manual includes a “Quick Start: 3-Step Programming”:

While you are locating the , here is the standard operational logic for 90% of XMTG2000 units. This will help you get up and running immediately. xmtg2000 temperature controller manual pdf top

The controller features an intuitive four-button interface that is similar across most models.

Terminals for the internal relay (for contactors) or SSR drive (voltage pulse). Parameter Settings: Pressing and holding the key usually enters the configuration menu. P, I, and D values: P, I, and D values: What or component

What or component is the controller driving? (SSR, mechanical contactor, or valve)

The XMTG-2000 isn't just a basic thermostat; it's packed with features that make it a preferred choice for industrial control: the parameter codes (P

| | Function | Description & Options | Typical Value | | :--- | :--- | :--- | :--- | | INP | Input Type | Defines which sensor is connected. K : K-Thermocouple, J : J-Thermocouple, PT : Pt100 RTD, CU : Cu50 RTD. | K | | INPH | Sensor Range High | Sets the high limit of the sensor. | 1000 | | INPL | Sensor Range Low | Sets the low limit of the sensor. | 0 | | CtrL | Control Method | PID : PID Algorithm, ONF : Simple ON/OFF Control. | PID | | P (Pb) | Proportional Band | Control amplification. A smaller value means a stronger response. | 100 | | I | Integral Time | Eliminates static errors. A larger value means a weaker correction. | 240 | | D | Derivative Time | Prevents overshoot. A larger value means a stronger braking effect. | 60 | | T | Control Cycle | Output period time (seconds). | 20 | | HY | Hysteresis | For ON/OFF mode: Prevents relay chattering near the set point. | 2 | | AL1 / AL2 | Alarm Value | Sets the temperature threshold for alarm 1 and 2 activation. | 100 | | HYA | Alarm Hysteresis | The differential value for resetting an alarm. | 2 | | SCb | PV Bias Correction | Allows you to manually adjust the displayed temperature value for calibration (positive or negative value). | 0.0 | | LOCK | Parameter Lock | 0000 : Unlocked, 0001 : Locked. 808 : Full unlock (common). | 0 |

The XMTG2000 series includes various models (such as the XMTG-2000, XMTG-1000, and variations for specific voltage inputs). While they all operate on similar principles, the parameter codes (P, I, D settings) and alarm configurations can differ slightly between manufacturers.

The user interface is quite consistent across all XMTG models. It uses a simple and effective design for monitoring and programming.